Olympiahalle, Innsbruck (A)
The fire-resistant glass Steindl Sicurofire as class Ei glass and Steindl Sicuroflam as class E glass provide guaranteed protection against heat and fire. Both types of glass have the largest maximum area in their respective classes in Europe.
Tested dimensions according to DIN 4102, Part 13 and ÖNORM B 3800, Ü-Zeichen (industry-wide agreement in Germany)
| Vertcal installation |
1.500 x 3.500 mm |
| Horizonal installation |
1.000 x 3.000 mm or 1.650 x 2.500 mm |
| max. pane format | 1.500 x 2.933 mm |
Steindl Sicurofire is a fire-resistant glass with a thermal shield function.
As a result of the particular make-up of the fire-resistant layer, Sicurofire is completely UV-resistant - without an extra filter. Sicurofire is ideally suited for exterior use as an insulation unit (up to Ug value of 1.1W/m²K).
| Type | fireresistance class DIN 4102 |
Thickness [mm] |
Weight [kg/m²] |
Ug value [W/m²K] |
Assessed sound insulation value [dB] |
Light transmission [%] |
Usage |
| Sicurefire Ei30/12 mono | Ei30 |
20/22 |
35/40 | 5,8 | 42 | 85 | interior and exterior |
| Sicurofire Ei60/22 mono | Ei60 | 32 | 2 | 5,8 | 44 | 85 | interior and exterior |
| Sicurofire Ei90/28 mono | Ei90 | 38 | 60 | 5,8 | 46 | 85 | interior and exterior |
| Sicurofire Ei30/12 ISO 3,0 W/m²K | Ei30 | 34/36 | 45/50 | 3,0 | 43 | 75 | exterior |
| Sicurofire Ei60/22 ISO 3,0 W/m²K | Ei60 | 46 | 62 | 3,0 | 45 | 75 | exterior |
| Sicurofire Ei90/28 ISO 3,0 W/m²K | Ei90 | 52 | 70 | 3,0 | 46 | 75 | exterior |
| Sicurofire Ei30/12 ISO 1,1 W/m²K | Ei30 | 34/36 | 45/50 | 1,1 | 43 | 70 | exterior |
| Sicurofire Ei60/22 ISO ISO 1,1 W/m²K |
Ei60 | 46 | 62 | 1,1 | 45 | 70 | exterior |
| Sicurofire Ei90/28 ISO 1,1 W/m²K |
Ei90 | 52 | 52 | 1,1 | 46 | 70 | exterior |
Fire-resistant glass of fire-resistance class E30. It prevents the spread of fire and smoke for at least 30 minutes. Sicuroflam safety glass is also completely pervious to light in the event of fire. It is available in thicknesses of 6, 8, 10 and 12 mm up to a maximum size of 150 cm x 300 cm.
Particular advantages: In addition to the fire-resistance function, Sicuroflam also exhibits all the safety characteristics of single-pane safety glass to DIN 1249 part 12.
Sicuroflam Plan is the first tested fire-resistant glass with a tested maximum size of 150 x 350 cm and with ground edges allowing flush glazing in 10 and 12 mm thicknesses.
Quality certification: DIN 4102, Part 13 and ÖNORM B 3800
| Type | Ö-Norm B3800 Teil 3 | Thickness [mm] |
Weight [kg/m²] |
Ug value [W/m²K] |
Assessed sound insulation value [dB] |
Light transmission [%] |
| Sicuroflam E30/6 | E30 | 6 | 15 | 5,8 | 32 | 89 |
| Sicuroflam E30/8 | E30 | 8 | 20 | 5,8 | 34 | 88 |
| Sicureflam E30/10 | E30 | 10 | 25 | 5,8 | 35 | 87 |
| Sicuroflam E30/12 | E30 | 12 | 30 | 5,8 | 37 | 86 |
| Sicuroflam E30/6/SZR/12/6 3,0 W/m²K | E30 | 24 | 30 | 3,0 | 33 | 81 |
| Sicuroflam E30/8/SZR/12/8 3,0 W/m²K | G30 | 28 | 40 | 3,0 | 34 | 80 |
| Sicuroflam E30/6/SZR/12/6 1,5 W/m²K | E30 | 24 | 30 | 1,3/1,5 | 33 | 75 |
| Sicuroflam E30/8/SZR/12/8 1,5 W/m²K | E30 | 28 | 40 | 1,3/1,5 | 34 | 73 |

Blue Tower, St. Johann (A)
Mutterhaus, München (D)
Sicurofire meets the manufacturer's fireproofing requirements when the following directions for installation are complied with. These minimal requirements guarantee continuous insulation of the pane surface area, glass periphery and frame. This is the only way to ensure that no intolerably high temperature differences occur at the glazing rebate. More...
STEINDL Sicuroflam is a fire-resistant glass of fire-protection class E30, that as a result of its enclosing function prevents the spread of fire and smoke for at least 30 minutes.
Sicuroflam E30 was developed for optimum fire protection in situations requiring low cost and with guaranteed short delivery times. More...
Sicuroflam Line is a further development of STEINDL Sicuroflam E30 to enable the extension of the architectural design possibilities. More...
Sicurofoam meets the manufacturer's fireproofing requirements when the following directions for installation are complied with. These minimal requirements guarantee continuous insulation of the pane surface area, glass periphery and frame. This is the only way to ensure that no intolerably high temperature differences occur at the glazing rebate. More...
The following test certificates document the quality and performance capabilities of our products.